modbus_server_transport.c File Reference

Transport protocol abstraction layer. More...

Go to the source code of this file.

Macros

#define TRACE_LEVEL   MODBUS_TRACE_LEVEL
 

Functions

void modbusServerAcceptConnection (ModbusServerContext *context)
 Accept connection request. More...
 
error_t modbusServerShutdownConnection (ModbusClientConnection *connection)
 Shutdown network connection. More...
 
void modbusServerCloseConnection (ModbusClientConnection *connection)
 Close network connection. More...
 
error_t modbusServerSendData (ModbusClientConnection *connection, const void *data, size_t length, size_t *written, uint_t flags)
 Send data using the relevant transport protocol. More...
 
error_t modbusServerReceiveData (ModbusClientConnection *connection, void *data, size_t size, size_t *received, uint_t flags)
 Receive data using the relevant transport protocol. More...
 

Detailed Description

Transport protocol abstraction layer.

License

SPDX-License-Identifier: GPL-2.0-or-later

Copyright (C) 2010-2024 Oryx Embedded SARL. All rights reserved.

This file is part of CycloneTCP Open.

This program is free software; you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation; either version 2 of the License, or (at your option) any later version.

This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details.

You should have received a copy of the GNU General Public License along with this program; if not, write to the Free Software Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA.

Author
Oryx Embedded SARL (www.oryx-embedded.com)
Version
2.4.0

Definition in file modbus_server_transport.c.

Macro Definition Documentation

◆ TRACE_LEVEL

#define TRACE_LEVEL   MODBUS_TRACE_LEVEL

Definition at line 32 of file modbus_server_transport.c.

Function Documentation

◆ modbusServerAcceptConnection()

void modbusServerAcceptConnection ( ModbusServerContext context)

Accept connection request.

Parameters
[in]contextPointer to the Modbus/TCP server context

Definition at line 50 of file modbus_server_transport.c.

◆ modbusServerCloseConnection()

void modbusServerCloseConnection ( ModbusClientConnection connection)

Close network connection.

Parameters
[in]connectionPointer to the client connection

Definition at line 236 of file modbus_server_transport.c.

◆ modbusServerReceiveData()

error_t modbusServerReceiveData ( ModbusClientConnection connection,
void *  data,
size_t  size,
size_t *  received,
uint_t  flags 
)

Receive data using the relevant transport protocol.

Parameters
[in]connectionPointer to the client connection
[out]dataBuffer into which received data will be placed
[in]sizeMaximum number of bytes that can be received
[out]receivedNumber of bytes that have been received
[in]flagsSet of flags that influences the behavior of this function
Returns
Error code

Definition at line 318 of file modbus_server_transport.c.

◆ modbusServerSendData()

error_t modbusServerSendData ( ModbusClientConnection connection,
const void *  data,
size_t  length,
size_t *  written,
uint_t  flags 
)

Send data using the relevant transport protocol.

Parameters
[in]connectionPointer to the client connection
[in]dataPointer to a buffer containing the data to be transmitted
[in]lengthNumber of bytes to be transmitted
[out]writtenActual number of bytes written (optional parameter)
[in]flagsSet of flags that influences the behavior of this function
Returns
Error code

Definition at line 284 of file modbus_server_transport.c.

◆ modbusServerShutdownConnection()

error_t modbusServerShutdownConnection ( ModbusClientConnection connection)

Shutdown network connection.

Parameters
[in]connectionPointer to the client connection
Returns
Error code

Definition at line 168 of file modbus_server_transport.c.